電腦的噪音測試規範當屬ISO7779或ECMA-074,必須符合以下規定:
Ø 聲音檔案要真實貯存,不可使用如杜比降噪(Dolby)等潤飾
Ø 1/3 octave band重視100~10k HZ,octave band重視125~8000 Hz
Ø 定電壓、定轉速…等,可容許誤差為5%
Ø 不論測SPL或PWL,測量靈敏度至少0.5dB,0.1dB更佳
Ø Peak>3dB(即△LI>3)視為衝擊音(impulsive)
Ø 測試時間一般至少3 cycle或4sec;SPL最好用1/3 octave band、A Weighting並註明operator or bystander position
PWL (sound power level)(ISO3744): Mic. position
Mic. |
x/r |
y/r |
z/r(H) |
離圓心投影距離 |
1 |
-.99 |
0 |
.15 |
.990 |
2 |
.50 |
-.86 |
.15 |
.995 |
3 |
.50 |
.86 |
.15 |
.995 |
4 |
-.45 |
.77 |
.45 |
.892 |
5 |
-.45 |
-.77 |
.45 |
.892 |
6 |
.89 |
0 |
.45 |
.890 |
7 |
-.33 |
.57 |
.75 |
.659 |
8 |
-.66 |
0 |
.75 |
.660 |
9 |
.33 |
-.57 |
.75 |
.659 |
10 |
0 |
0 |
1 |
0 |
Unit: m |
Ø Calibration
Calibrator準確性應在0.3dB內
ISO6926建議每年應校正一次,若使用不同計算方式(如:1/3octave band、FFT…)發現落差超過0.5dB,則須進行校正
IEC61672-1則建議兩年校正一次
Ø Test Environment (Follow ISO3744 3745)
Barometric pressure: 86k~106k Pa
Temperature: 15~30℃,最好23±2℃
Relative humidity: 40~70%
Ø Microphone position
ISO7779建議Mic.與待測物距離1m,若聲音很小,則距離最近可至25cm;ECMA-074則建議距離最近為50cm
Mic.不可暴露於風流處,否則應使用防風罩等保護設備
Ø 無響室物品放置距離
Floor-standing:待測物至少離牆2m,物品間至少相距10cm
Table-top or Wall-mounted:待測物至少離牆1.5m,物品間至少相距10cm
Hand-held:至少離地10cm
Sub-assemblies:至少離地25cm
Ø 殘響室物品放置距離
Floor-standing:待測物至少離牆1.5m
Table-top or Wall-mounted:待測物至少離牆1.5m
Ø Idle mode and Operating mode
Idle mode只有一種,但Operating mode可有多種,但要標示清楚
操作過程中若有一次或不超過一天8hr的5%(即24min),且為過程中一定會有的較大音量,可視為idle
有的機器操作久了會進入休眠或螢幕保護狀態,測試時應避免,若無法避免則必須於報告中詳述
操作過程中有時會有警示音或鈴聲,應設法避免或降至最低
Ø 印表機測試
每2.54cm印10個字母,單張送紙使用70或80g/m2A4;連續紙(折疊型或滾筒型)用50或60g/m2A4
紙張要在測試環境(23±20C、40~70%...)下放24hr
測試時間:單張紙(多為A4)每張需印60%面積,至少三張;摺疊紙至少三張;滾筒型比照單張紙長寬的60%;存款簿印表機則要測完整插入、印完、到吐出的時間
Idle mode僅開啟power。
Operating mode即printing mode,分為keyboard operating mode(local or transmission mode)與automatic operating mode(local or on-line mode)
Ø 鍵盤測試
有專屬的自動打字裝置,設定每秒敲5個字母,機器操作的聲音納入背景音量設定
Ø 顯示器測試
分為idle mode、power saving mode與operating mode(指typing mode,打字模式,如可以的話就測)三種,Screen在16k Hz處常會有較大的噪音或不連續的tone值,如有此狀況則應全頻域呈現,不可只截取100~10k Hz